Cleanova’s CleanMax cartridge filters remove high volumes of solid contaminants to Beta 5000 efficiency levels while ensuring minimal impact on process parameters. Each CleanMax filter cartridge features a unique layered and pleated media pack construction, designed for maximum particle retention and absolute rated performance across a wide range of particulate sizes. The inside-to-out flow pattern combined with a positive O-ring seal arrangement guarantees high efficiency contaminant removal and increased dirt-holding capacity, prolonging service life. The filter cartridge is designed for efficient removal and replacement, ensuring that all trapped particles are securely contained and do not fall into the clean side of the filter housing. CleanMax filter cartridges are available with polypropylene and glass microfiber filtration media in absolute Beta 5000 (99.98%) ratings from 1 to 40 microns.
PRODUCT FEATURES
- Layered and pleated filter media
- Increased dirt-holding capacity
- Maximum particle retention
- Beta 5000 (99.98% filtration efficiency)
- Large surface area
- Efficient particulate removal
- Inside-to-out flow pattern
- Extended service life
CONSTRUCTION
- Length: 508mm – 2032mm (20.0” – 80.0”)
- Cartridge Diameter: 152mm (6.0”)
- Filter Media: glass fibre with polyester, polypropylene
- Support: polypropylene, stainless steel
- End Caps: glass-filled polypropylene
- Gaskets/O-Rings: silicone, nitrile, EPDM, Viton®
RECOMMENDED OPERATING CONDITIONS
- Max Operating Temperature: Polypropylene – 82°C, Glass fibre – 110°C
- Max Differential Pressure: 2.5 – 3.0 barg changeout
MICRON RATINGS (ABSOLUTE)
- 1μm, 2μm, 5μm, 10μm, 20μm, 40μm
- ßX = 5000 (99.98%)